Apply the remover or remover gel with a brush or cloth, allow 3 minutes to solve the graffiti, then remove the remover with the graffiti. We advise to remove Graffiti within one week. For older or heavier graffiti the treatment may have to be repeated.
First apply the remover gel, after 3 minutes remove the gel with a (paper) towel or cloth. Then give the area a final wipe with the standard remover on a cloth or a graffiti wipe. In this way no substance will be absorbed in the ground and the cleaning materials can be disposed of as chemical waste.
Dilute Recoat Bonding Agent standard 1:1 with water. Apply Recoat Bonding Agent evenly over the surface with a cleaning mop and then allow to dry.
Evaluation of the substrate is very important. The substrate must be clean, dry, and have good load-bearing capacity, free from green deposits, oil, and grease, among other things.
– Pre-cast concrete substrates must first be treated with Recoat Etching Cleaner (see TDS). For untreated and highly absorbent substrates, depending on the absorption, the primer should be strongly diluted (20-30%) with water.
– Ceramic substrates must first be cleaned with a scouring pad in combination with Recoat Floor Cleaner (see TDS), and then moistened with Bonding Agent (see TDS).
– Recoat Multi Primer Plus reduces consumption and ensures optimal performance of the final product. Apply the product as a “normal” water-based paint; apply, spread, and leave it alone.
Avoid working in the sun due to too fast drying.
Ensure adequate ventilation, as this accelerates the drying process.
Never apply Recoat products undiluted.
It is recommended to always make a test patch.
Apply the Recoat Etching Cleaner evenly to the concrete. Scrub the concrete with a stiff brush, sanding cloth or sanding pad and make sure that the concrete stays wet.
After 5 minutes, rinse away the Recoat Etching Cleaner with the dirt with clean water and let the concrete dry. For the best result, work in sections of 3 x 3 meters.
Rinse the entire surface again with water after all parts have been treated with Recoat Etching Cleaner.
After drying, no powder should be left behind, otherwise repeat the treatment.
Remove lose dust/grit with a vacuum cleaner, floor mop or other dry cleaning method.
Pretreatment before coating:
Depending on the level of contamination the Recoat Floor Cleaner can be diluted from 1:5 (standard) for normal cleaning, to 1:2 (1 litre cleaner to 2 litres of water) for deep cleaning.
Apply the diluted Recoat Floor Cleaner on a section of the floor by spray or mop.
Leave the solution on the substrate for 3-5 minutes to solve the embedded contamination. Scrub the treated section with a polishing machine or auto scrubber equipped with a white or red pad and remove all the dissolved contamination. When the entire floor is cleaned like this make one more overall run with the auto scrubber holding only clean water in the tank making sure to remove all cleaning residues.
Note: keep the quantity of water used for cleaning to a minimum. Be aware of large openings/crevices in the floor. Do not allow excessive amounts of cleaning solution in to run in the openings/crevices .
Note: when using the Recoat Floor Cleaner in high concentrations allow 2-3 hours drying time before using the floor.
For regular floor cleaning:
Dilute Floor Cleaner 1:50 to 1:100
Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.
– First clean prefab concrete with the Recoat Etching Cleaner (see-TDS). For untreated and highly absorbent substrates depending on the suction, dilute the primer strongly (20-50%) with water.
– First clean ceramic surfaces with a sanding cloth in combination with the Recoat Bonding Cleaner (see TDS).
– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.
– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Cleaner (see TDS).
– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.
Recoat Multi Primer reduces consumption and ensures optimum performance of the end product. Apply product as a “normal” waterborne paint; applying, distributing and holding off. Avoid working in the sun because of too fast drying.
Never apply Recoat products undiluted.
Advice to always make a test surface.
The substrate must be completely clean, dry and free of grease and other contaminants. Assessment of the substrate is very important. Before applying first properly mix the coating because of the sagging matt paste.
Apply the coating with a microfibre roller. Absorbent substrates must be treated twice. Thin the first layer with 5-10% of water and apply the second layer without thinning the coating. Try to apply a proper layer thickness of the coating and check this with a layer thickness comb. Always use the wet-on-wet approach. Never apply recoat products undiluted. Always pre-treat plastic surfaces with Recoat Multi Pirmer in connection with plasticizers.
Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.
– First clean ceramic surfaces with a sanding cloth in combination with the Recoat Bonding Cleaner (see TDS).
– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.
– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Cleaner (see TDS).
– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.
Then pre-treat all surfaces with the Recoat Multi Primer Clear.
Recoat Multi Primer reduces consumption and ensures optimum performance of the end product.
Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.
– First clean ceramic surfaces with a sanding cloth in combination with the Recoat Bonding Cleaner (see TDS).
– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.
– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Cleaner (see TDS).
– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.
Then pre-treat all surfaces with the Recoat Multi Primer Clear. Recoat Multi Primer reduces consumption and ensures optimum performance of the end product.Always use the wet-on-wet approach.
Products should be applied as ‘normal’ waterborne products; apply, divide and leave alone. Avoid working in the sun because of the quick drying. Never apply Recoat products without thinning it on beforehand. Advice to always make a test surface.
Always pre-treat plastic surfaces with Recoat Multi Pirmer in connection with plasticizers.
Assessment of the subsoil is very important. The surface must be clean, dry and load-bearing, free, skin grease, oil etc.
Clean the surface with Recoat Floor cleaner
Then pre-treat the surface with the Recoat Multi Primer or recoat Stix and after 2-12 hours apply Recoat Floor One Plus. (see TDS sheets concerning products)
Always make sure you work wet in wet. Apply product as a “normal” water-borne lacquer; apply, distribute and stay off. Avoid working in the sun because of too fast drying. Try not to apply thick layers. Never apply recoat products undiluted.
Advice to always make a test surface.
Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.
– First clean concrete substrates such as prefab concrete and other absorbent substrates with the Recoat Etching Cleaner (see TDS)
For untreated and highly absorbent substrates depending on the suction, dilute the primer strongly (20-50%) with water.
– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.
– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Agent. (see TDS)
– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.Recoat Multi Primer reduces consumption and ensures optimum performance of the end product. Always use the wet-on-wet approach.
Apply the product, distribute evenly and leave alone. Avoid working in the sun because of too fast drying.Never apply Recoat products undiluted.
Advice to always make a test surface and to prepare with Recoat Multi primer.
The finishing coat must be applied no later than 48 hours after the application of the first layer.
Assessment of the substrate is very important. The surface must be clean, dry and load-bearing, free, skin grease, oil etc.
Clean the surface with Recoat Floor cleaner
Then pre-treat the surface with the Recoat Multi Primer and after 2-12 hours apply Recoat Floor One XS. (see TDS sheets concerning products)
Always make sure you work wet in wet. Apply product as a “normal” water-borne lacquer; apply, distribute and stay off. Avoid working in the sun because of too fast drying. Try not to apply thick layers. Never apply recoat products undiluted.
Advice to always make a test surface.
Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.
– First clean prefab concrete substrates with the Recoat Etching Cleaner (see TDS)
– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.
– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Agent. (see TDS)
– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.
Then pre-treat all surfaces with the Recoat Multi Primer clear
Recoat Multi Primer reduces consumption and ensures optimum performance of the end product.
Apply the Recoat Anti Graffiti Matt within 48 hours of applying the Recoat Multiprimer.
Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.
– First clean prefab concrete substrates with the Recoat Etching Cleaner (see TDS)
– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.
– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Agent. (see TDS)
– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.
Then pre-treat all surfaces with the Recoat Multi Primer clear
Recoat Multi Primer reduces consumption and ensures optimum performance of the end product.
Apply the Recoat Anti Graffiti Gloss within 48 hours of applying the Recoat Multiprimer.
The assessment of the substrate is very important. The surface should be clean, dry and load-bearing, free from skin grease, oil, etc.
Clean the surface with Recoat Floor Cleaner.
Then pre-treat the surface with Recoat Stix UV and after drying apply Recoat Floor UV with a microfibre roller 8-9 mm.
(See TDS sheets for products)
After drying, the Floor UV coating can be cured with a UV lamp.
Drying can be accelerated by using fans (1/2 hour).
Always make sure to work wet in wet. Apply the product like a ‘normal’ water-based paint; apply, distribute and keep off. Avoid working in the sun because of too fast drying. Do not apply thick layers!
Assessment of the substrate is very important. The surface must be clean, dry and load-bearing, free, skin grease, oil etc.
Clean the surface with Recoat Floor cleaner
Then pre-treat the surface with the Recoat Multi Primer and after 2-12 hours apply Recoat Floor One XS. (see TDS sheets concerning products)
Always make sure you work wet in wet. Apply product as a “normal” water-borne lacquer; apply, distribute and stay off. Avoid working in the sun because of too fast drying. Try not to apply thick layers. Never apply recoat products undiluted.
Advice to always make a test surface.
Recoat Anti Graffiti Gloss is a clear, waterborne 2k coating with anti-graffiti characteristics, which is suitable for various substrates for inside and outside use. Recoat Anti Graffiti Gloss has excellent adhesion properties.
After pre-treatment with Recoat Multi Primer clear a permanent, gloss, transparent, protective layer will form.
Recoat Anti Graffiti Gloss protects the surfaces from persistent dirt adherence and therefore is very easy to clean.
In addition, graffiti will not attach to the surface and is therefore really easy to remove with Recoat Graffiti Remover.
Recoat AG Gloss is highly resistant to chemicals, AV A and UV B resistant and highly rust resistant. Chewing gum, stickers and posters will not stick.
Treated surfaces are not only repaired but also permanently protected against dirt, water, weathering and attachment of biofilm.
As a result, treated surfaces remain clean for longer and retain their original condition. This eliminates the need for frequent maintenance.
Recoat Anti Graffiti Gloss can be applied to concrete substrates, façade cladding, plastics, various steel surfaces, aluminium (coated or untreated), stickers, posters, wallpaper etc.
We always advise to perform a test application.
Recoat coatings are applicable in many sectors, including real estate, infrastructure engineering ans civil engineering. Due to its simplicity, the Recoat system is a sustainable and less expensive alternative for the maintenance of many typers of substrates.
Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.
– First clean prefab concrete substrates with the Recoat Etching Cleaner (see TDS)
– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.
– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Agent. (see TDS)
– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.
Then pre-treat all surfaces with the Recoat Multi Primer clear
Recoat Multi Primer reduces consumption and ensures optimum performance of the end product.
Apply the Recoat Anti Graffiti Gloss within 48 hours of applying the Recoat Multiprimer.
Volume | |
---|---|
Mixed volume | 750 MILLILITER |
Base | Clear waterborne 2K coating |
Colour | Clear |
Mix ratio | 4 : 1 (Recoat base : Recoat hardener). Stir base mechanical before adding hardener for 1 minute. Mix base and hardener mechanical (min 3 min.) without adding water. Then add 20% water and mix again for 3 minutes. |
Output | Approx. 12 m2 – 15 m2 / liter Is practical per litre of applied product. The output depends on the application method, roughness, structure and porosity of the substrate. |
Gloss strength | Gloss 85 GU |
Potlife at 20°C | 2 to 3 hours |
Relative humidity | A maximum of 80% |
Application temperature | 10 – 30 °C |
Application by means of | Felt roller, Microfibre roller 8-9 mm |
VOC content | 75 g/L. The product is suitable for indoor and outdoor use. EU limit for this product (catA/d): 140 g/L. |
Approximate specific density | 1,01 KG/L |
Volume fixed percentage | 41% |
Outdoor durability | 8 to 10 year durability, provided that application is carried out in accordance with regulations and depending on the condition of the substrate, location and use, as well as normal maintenance., With frequent removal of graffiti, the coating may last less time. |
Drying at 20 °C | Dust dry after 20 min, Thumb-tight after 4-6 hours, Cleanable after 7 days |
Application | Wear gloves and ensure sufficient ventilation |
Hardening | Full load can take longer due to varying temperatures. Minimum 5 days at a constant temperature of 20 °C. |
Cleaning materials | Recoat Cleaner, Water |
Recommended Layer Thickness | Wet: 60 to 85 micrometres, Dry: 25 to 35 micrometres |
Transport | Temperature during storage, transport and application minimum 5° C and maximum 30°C at a relative humidity of Maximum 85% |
Thinning | Water 20% |
Storage stability | A maximum of 24 months in case of dry storage and a temperature of 5°C to 30°C., Hardener for a maximum of 12 months in case of dry storage and a temperature of 5°C to 30°C |
Schaafdries 12
5371 NJ Ravenstein
Nederland