Recoat – Stix UV

  • Pre-treatment for Recoat Floor UV
  • Easy to apply with a microfibre polish dispenser

Apply the Recoat Etching Cleaner evenly to the concrete. Scrub the concrete with a stiff brush, sanding cloth or sanding pad and make sure that the concrete stays wet.

After 5 minutes, rinse away the Recoat Etching Cleaner with the dirt with clean water and let the concrete dry. For the best result, work in sections of 3 x 3 meters.

Rinse the entire surface again with water after all parts have been treated with Recoat Etching Cleaner.

After drying, no powder should be left behind, otherwise repeat the treatment.

Apply the remover or remover gel with a brush or cloth, allow 3 minutes to solve the graffiti, then remove the remover with the graffiti. We advise to remove Graffiti within one week. For older or heavier graffiti the treatment may have to be repeated.


First apply the remover gel, after 3 minutes remove the gel with a (paper) towel or cloth. Then give the area a final wipe with the standard remover on a cloth or a graffiti wipe. In this way no substance will be absorbed in the ground and the cleaning materials can be disposed of as chemical waste.

Dilute Recoat Bonding Agent standard 1:1 with water. Apply Recoat Bonding Agent evenly over the surface with a cleaning mop and then allow to dry.

Clean the substrate with Recoat Cleaner (see TDS).Divide Recoat Stix Flex evenly over the substrate, rub gently, do not polish. Drying time appr. 15 minutes. Then finish with Recoat AM Protector® Flex.User advice: preferably use a microfibre cloth for application. After use store the microfibre cloth in a seal bag or airtight packing, to prevent the cloth from drying out. This will enhance the lifetime of the cloth.

Evaluation of the substrate is very important. The substrate must be clean, dry, and have good load-bearing capacity, free from green deposits, oil, and grease, among other things.

– Pre-cast concrete substrates must first be treated with Recoat Etching Cleaner (see TDS). For untreated and highly absorbent substrates, depending on the absorption, the primer should be strongly diluted (20-30%) with water.

– Ceramic substrates must first be cleaned with a scouring pad in combination with Recoat Floor Cleaner (see TDS), and then moistened with Bonding Agent (see TDS).

– Recoat Multi Primer Plus reduces consumption and ensures optimal performance of the final product. Apply the product as a “normal” water-based paint; apply, spread, and leave it alone.

Avoid working in the sun due to too fast drying.

Ensure adequate ventilation, as this accelerates the drying process.

Never apply Recoat products undiluted.

It is recommended to always make a test patch.

Remove lose dust/grit with a vacuum cleaner, floor mop or other dry cleaning method.

Pretreatment before coating:

Depending on the level of contamination the Recoat Floor Cleaner can be diluted from 1:5 (standard) for normal cleaning, to 1:2 (1 litre cleaner to 2 litres of water) for deep cleaning.

Apply the diluted Recoat Floor Cleaner on a section of the floor by spray or mop. 

Leave the solution on the substrate for 3-5 minutes to solve the embedded contamination. Scrub the treated section with a polishing machine or auto scrubber equipped with a white or red pad and remove all the dissolved contamination. When the entire floor is cleaned like this make one more overall run with the auto scrubber holding only clean water in the tank making sure to remove all cleaning residues.

Note: keep the quantity of water used for cleaning to a minimum. Be aware of large openings/crevices in the floor. Do not allow excessive amounts of cleaning solution in to run in the openings/crevices .

Note: when using the Recoat Floor Cleaner in high concentrations allow 2-3 hours drying time before using the floor.


For regular floor cleaning:

Dilute Floor Cleaner 1:50 to 1:100

Apply the Recoat Cleaner evenly to the surface while rubbing and let dry. The surface doesn’t need to be rinsed with water,
Clean the substrate with Recoat Cleaner (see TDS).Divide Recoat Stix evenly over the substrate, rub gently, do not polish. Drying time appr. 10 minutes. Can be recoated when dry.User advice: preferably use a microfibre cloth for application. After use store the microfibre cloth in a seal bag or airtight packing, to prevent the cloth from drying out. This will enhance the lifetime of the cloth.

Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.

– First clean prefab concrete with the Recoat Etching Cleaner (see-TDS). For untreated and highly absorbent substrates depending on the suction, dilute the primer strongly (20-50%) with water.

– First clean ceramic surfaces with a sanding cloth in combination with the Recoat Bonding Cleaner (see TDS).

– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.

– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Cleaner (see TDS).

– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.

Recoat Multi Primer reduces consumption and ensures optimum performance of the end product. Apply product as a “normal” waterborne paint; applying, distributing and holding off. Avoid working in the sun because of too fast drying.

Never apply Recoat products undiluted.

Advice to always make a test surface.

Surface Preparation:
Thoroughly clean the surface using Recoat Floor Cleaner to remove dirt, grease, and other contaminants. For detailed instructions, please refer to the TDS sheet of Recoat Floor Cleaner.

Always apply a layer of Recoat Multi Primer Clear as a base for Recoat Stix UV on stripped linoleum.

Applying Recoat Stix UV:
Evenly distribute Recoat Stix UV over the surface. The best application is with a Polish applicator and a microfiber cloth (t-bar). This prevents splattering and material waste, ensuring an even spread.

Drying Time:
Allow Recoat Stix UV to dry for approximately 20 minutes. Once dry, the floor can be coated with Recoat Floor UV for a flawless finish.

User Advice:
Use a microfiber cloth for optimal application.
After use, store the microfiber cloth in a sealable bag or airtight container to prevent it from drying out. This will significantly extend the lifespan of the cloth.

Finishing:
After Recoat Stix UV has dried, immediately apply Recoat Floor UV for the best results.

The substrate must be completely clean, dry and free of grease and other contaminants. Assessment of the substrate is very important. Before applying first properly mix the coating because of the sagging matt paste.


Apply the coating with a microfibre roller. Absorbent substrates must be treated twice. Thin the first layer with 5-10% of water and apply the second layer without thinning the coating. Try to apply a proper layer thickness of the coating and check this with a layer thickness comb. Always use the wet-on-wet approach. Never apply recoat products undiluted. Always pre-treat plastic surfaces with Recoat Multi Pirmer in connection with plasticizers.

Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.

– First clean ceramic surfaces with a sanding cloth in combination with the Recoat Bonding Cleaner (see TDS).

– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.

– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Cleaner (see TDS).

– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.

Then pre-treat all surfaces with the Recoat Multi Primer Clear.

Recoat Multi Primer reduces consumption and ensures optimum performance of the end product.

Always use the wet-on-wet approach. Products should be applied as ‘normal’ waterborne products; apply, divide and leave alone.
Avoid working in the sun because of the quick drying. 
Never apply Recoat products without thinning it on beforehand.
Advice to always make a test surface.

Always pre-treat plastic and polysester surfaces with Recoat Multi Pirmer or Recoat Stix in connection with plasticizers.
  • Clean/degrease thoroughly with Recoat Cleaner until no residue is left.
  • Pre-treat the substrate with Recoat Multi Primer.
  • After drying (1 to 2 hours), apply Recoat Silk.
  • Apply with a 8-9 mm microfiber roller and a brush suitable for water-based coatings.

Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.

– First clean ceramic surfaces with a sanding cloth in combination with the Recoat Bonding Cleaner (see TDS).

– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.

– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Cleaner (see TDS).

– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.

Then pre-treat all surfaces with the Recoat Multi Primer Clear. Recoat Multi Primer reduces consumption and ensures optimum performance of the end product.Always use the wet-on-wet approach.

Products should be applied as ‘normal’ waterborne products; apply, divide and leave alone. Avoid working in the sun because of the quick drying. Never apply Recoat products without thinning it on beforehand. Advice to always make a test surface.

Always pre-treat plastic surfaces with Recoat Multi Pirmer in connection with plasticizers.

Assessment of the subsoil is very important. The surface must be clean, dry and load-bearing, free, skin grease, oil etc.

Clean the surface with Recoat Floor cleaner

Then pre-treat the surface with the Recoat Multi Primer or recoat Stix and after 2-12 hours apply Recoat Floor One Plus.  (see TDS sheets concerning products)

Always make sure you work wet in wet. Apply product as a “normal” water-borne lacquer; apply, distribute and stay off. Avoid working in the sun because of too fast drying. Try not to apply thick layers.  Never apply recoat products undiluted. 

Advice to always make a test surface.

Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.

– First clean concrete substrates such as prefab concrete and other absorbent substrates with the Recoat Etching Cleaner (see TDS)

For untreated and highly absorbent substrates depending on the suction, dilute the primer strongly (20-50%) with water.

– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.

– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Agent. (see TDS)

– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.Recoat Multi Primer reduces consumption and ensures optimum performance of the end product. Always use the wet-on-wet approach.

Apply the product, distribute evenly and leave alone. Avoid working in the sun because of too fast drying.Never apply Recoat products undiluted.

Advice to always make a test surface and to prepare with Recoat Multi primer.

The finishing coat must be applied no later than 48 hours after the application of the first layer.

Assessment of the substrate is very important. The surface must be clean, dry and load-bearing, free, skin grease, oil etc.

Clean the surface with Recoat Floor cleaner

Then pre-treat the surface with the Recoat Multi Primer and after 2-12 hours apply Recoat Floor One XS.  (see TDS sheets concerning products)

Always make sure you work wet in wet. Apply product as a “normal” water-borne lacquer; apply, distribute and stay off. Avoid working in the sun because of too fast drying. Try not to apply thick layers.  Never apply recoat products undiluted. 

Advice to always make a test surface.

  • Thoroughly clean/degrease with Recoat Cleaner until no residue remains.
  • Moisten the surface (do not scrub!) with Recoat Stix using a lint-free cloth.
  • After drying (15-20 minutes), apply Recoat Stainless Steel Protector using a felt roller and a brush suitable for water-based paints.

Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.

–  First clean prefab concrete substrates with the Recoat Etching Cleaner (see TDS)

– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.

– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Agent. (see TDS)

– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.

Then pre-treat all surfaces with the Recoat Multi Primer clear

Recoat Multi Primer reduces consumption and ensures optimum performance of the end product.

Apply the Recoat Anti Graffiti Matt within 48 hours of applying the Recoat Multiprimer.

Always use the wet-on-wet approach. Products should be applied as ‘normal’ waterborne products; apply, divide and leave alone.
Avoid working in the sun because of the quick drying. 
Never apply Recoat products without thinning it on beforehand.
Advice to always make a test surface and to prepare with Recoat Multi primer.
Never apply two layers of anti-graffiti over each other within three months and without matting by sanding.

Assessment of the surface is very important. The surface must clean, dry and free of grease, oil and other contaminants.

–  First clean prefab concrete substrates with the Recoat Etching Cleaner (see TDS)

– First clean plastic surfaces with a sanding cloth in combination with the Recoat Cleaner.

– Metal (closed) surfaces first clean a sanding cloth in combination with the Recoat Bonding Agent. (see TDS)

– Other surfaces first clean a sanding cloth in combination with the Recoat Cleaner.

Then pre-treat all surfaces with the Recoat Multi Primer clear

Recoat Multi Primer reduces consumption and ensures optimum performance of the end product.

Apply the Recoat Anti Graffiti Gloss within 48 hours of applying the Recoat Multiprimer.

Always use the wet-on-wet approach. Products should be applied as ‘normal’ waterborne products; apply, divide and leave alone.
Avoid working in the sun because of the quick drying. 
Never apply Recoat products without thinning it on beforehand.
Advice to always make a test surface and to prepare with Recoat Multi primer.
Never apply two layers of anti-graffiti over each other within three months and without matting by sanding.

The assessment of the substrate is very important. The surface should be clean, dry and load-bearing, free from skin grease, oil, etc.

Clean the surface with Recoat Floor Cleaner.

Then pre-treat the surface with Recoat Stix UV and after drying apply Recoat Floor UV with a microfibre roller 8-9 mm. 

(See TDS sheets for products)

After drying, the Floor UV coating can be cured with a UV lamp.

Drying can be accelerated by using fans (1/2 hour).

Always make sure to work wet in wet. Apply the product like a ‘normal’ water-based paint; apply, distribute and keep off. Avoid working in the sun because of too fast drying. Do not apply thick layers! 

Assessment of the substrate is very important. The surface must be clean, dry and load-bearing, free, skin grease, oil etc.

Clean the surface with Recoat Floor cleaner

Then pre-treat the surface with the Recoat Multi Primer and after 2-12 hours apply Recoat Floor One XS.  (see TDS sheets concerning products)

Always make sure you work wet in wet. Apply product as a “normal” water-borne lacquer; apply, distribute and stay off. Avoid working in the sun because of too fast drying. Try not to apply thick layers.  Never apply recoat products undiluted. 

Advice to always make a test surface.

Recoat Stix UV is a high-quality adhesive and sealer in one, specially developed to ensure optimum adhesion and durable finish within the Recoat UV system. This product is ideal for use on virtually all indoor substrates, serving as the perfect pre-treatment for Recoat Floor UV. Recoat Stix UV not only ensures excellent adhesion, but it also seals the substrate and minimises the consumption of the finishing coat, contributing to a beautiful aesthetic end result.

Application of Recoat Stix UV is best done with a Polish distributor and microfibre cloth (t-bar), which prevents splashing and wastage of material. For best results, we recommend finishing with Recoat Floor UV immediately after drying.

Important tips:

  • Suitable for almost all substrates, for indoor applications.
  • Avoid direct sunlight during application to prevent too fast drying.

Recoat Stix UV reduces screed consumption and provides a long-lasting and aesthetic finish.

Recoat Stix UV: the perfect basis for a durable and beautiful end result.

Application area

Recoat Stix UV – The Ideal Pre-treatment Layer for Almost All Types of Floors

Recoat Stix UV is the perfect pre-treatment layer for nearly all types of floors. Whether it’s wood, concrete, or other surfaces, this product ensures optimal adhesion and seals the substrate for a long-lasting and smooth finish. For highly absorbent floors, we recommend using Recoat Multiprimer first for the best results.

With a fast drying time of just about 20 minutes, the topcoat can be applied shortly after applying Recoat Stix UV. To speed up the drying process even further, fans can be used. This allows you to work quickly and efficiently toward a high-quality finish for your floor.

Features:

  • Suitable for almost all floor surfaces.
  • Fast drying, within approximately 20 minutes.
  • Accelerated drying possible with fans.
  • Essential for highly absorbent substrates when used with Recoat Multiprimer.

Make your flooring projects faster and more durable with Recoat Stix UV.

Surface Preparation:
Thoroughly clean the surface using Recoat Floor Cleaner to remove dirt, grease, and other contaminants. For detailed instructions, please refer to the TDS sheet of Recoat Floor Cleaner.
Always apply a layer of Recoat Multi Primer Clear as a base for Recoat Stix UV on stripped linoleum.
Applying Recoat Stix UV:
Evenly distribute Recoat Stix UV over the surface. The best application is with a Polish applicator and a microfiber cloth (t-bar). This prevents splattering and material waste, ensuring an even spread.
Drying Time:
Allow Recoat Stix UV to dry for approximately 20 minutes. Once dry, the floor can be coated with Recoat Floor UV for a flawless finish.
User Advice:
Use a microfiber cloth for optimal application.
After use, store the microfiber cloth in a sealable bag or airtight container to prevent it from drying out. This will significantly extend the lifespan of the cloth.
Finishing:
After Recoat Stix UV has dried, immediately apply Recoat Floor UV for the best results.

Additional information

Volume

Base

High quality modified acrylate dispersions

Colour

Colourless

Output

Approx. 60 m2 – 80 m2 / liter The output depends on the application method, roughness, structure and porosity of the substrate.

Gloss strength

Semi Gloss GU

Relative humidity

A maximum of 80%

Application temperature

10 – 30 °C

Application by means of

Microfiber cloth

Approximate specific density

1,04

Volume fixed percentage

13%

Drying at 20 °C

Dry and ready for recoating after approximately 30 minutes

Application

Wear gloves and ensure sufficient ventilation

Cleaning materials

Recoat Cleaner, Water

Transport

Temperature during storage, transport and application minimum 5° C and maximum 30°C at a relative humidity of Maximum 85%

Thinning

Ready to use

Storage stability

Unopened, 12 months in a dark, dry place at a temperature of 10°C to 25°C.

Maintenance

Do not clean with alcoholic cleaning agents, Clean with Recoat Floor Cleaner diluted 1:50 to 1:100

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.